Fire pro

Advance CPVC Piping System for Fire Sprinkler System

Astral Fire Pro pipes and fittings are specifically designed for fire sprinkler systems. They are made from a specialized thermoplastic called Chlorinated Polyvinyl Chloride (CPVC). The use of Astral Fire Pro pipes and fittings offers several advantages in sprinkler installations, including excellent hydraulic performance, easy joining, increased hanger spacing compared to other thermoplastics, and simple assembly.

Astral Fire Pro has become the new industry standard for automatic fire sprinkler piping systems. These CPVC pipes and fittings are fully approved for use in various settings, including light and ordinary hazardous rooms or applications, as outlined by NFPA 13. This approval covers both new construction and retrofit projects, making Astral Fire Pro suitable for a wide range of buildings such as high-rise residential and commercial structures, schools, institutions, one and two-family dwellings, as well as hotels and hospitals.

Certifications

Enquire Now

Enquire Now


    Download Catalogue View Catalogue

    Features & Benefits

    • Ignition resistance
    • Burning resistance
    • Low friction loss
    • Temperature / pressure rating
    • Excellent Fire-Retardant Properties
    • No pre-cutting and expensive fabrication required
    • Easily connected to other sprinkler piping system
    • Flexibility in the piping for greater ease of installation
    • Resistant to rust, scale and foreign contaminant build up / Inexpensive tools required for installation
    • Easily repairing or modification on site
    • Designed to a 50 years life expectancy Astral Fire Pro pipes and fittings provide unique advantages in sprinkler installations including superior hydraulics, ease of joining, increased hanger spacing in comparison to other thermoplastics and ease of assembly.

    Fields of Application

    Approved for use in all light and ordinary hazardous rooms and other light hazard applications as per NFPA 13, in both new and retrofit construction, such as:

    • Schools and Institutions
    • One and Two family dwellings
    • Malls
    • Commercial complex
    • Hospital
    • Offices
    • Hotels and Hospitals Automatic Fire Sprinkler Application
    • High-rise buildings (including residential and commercial)

    Standards & Specifications

    • ASTM F442
    • IS 16088
    • IS 16534
    • ASTM F439
    • UL Listed

    Available Sizes

    • SDR 13.5 -20mm (¾”) to 80mm (3”)

    FAQs

    Astral Firepro Is made from a Specially Engineered Plastic Called Chlorinated Polyvinyl Chloride (CPVC).

    Astral Fire Pro possesses a Limiting Oxygen Index (LOI) of 60, indicating that it requires 60% oxygen concentration to melt when exposed to fire. Given that the atmosphere typically contains 20% oxygen, a forced combustion occurs on the outer surface of CPVC, leading to charring of the pipe. Interestingly, this charring effect acts as a protective layer for the inner surface of the pipe.

    Astral Fire Pro is suitable for use in wet sprinkler piping systems within light hazard occupancies, as defined by NFPA 13. It meets the necessary requirements and standards for such applications, providing a reliable and effective solution for fire protection in these types of environments.

    Astral Fire Pro holds UL and ISI listings for its pipes and fittings. This indicates that they have undergone rigorous testing and meet the quality and safety standards set by these organizations. Furthermore, Fire Pro has been given approval from individual state and city fire departments, allowing its usage in specific states and cities. These approvals highlight the recognition and acceptance of Astral Firepro's compliance with fire safety regulations in those particular regions.

    Astral Fire Pro offers cost-saving advantages across various aspects. Firstly, it simplifies installation, eliminating the need for highly skilled workers and thereby reducing installation costs. Additionally, Astral Fire Pro features a smooth internal surface with a high C value of 150. This allows for hydraulic calculations that can optimize the pipe size, potentially leading to cost savings in materials. Moreover, as Astral Firepro is resistant to corrosion, it entails lower maintenance costs over time compared to alternative piping materials. These combined benefits contribute to cost reduction and overall efficiency in fire sprinkler system installations.

    New Updates

    Reducing Tee
    Type RINGFIT
    View Details
    Reducing Tee With Door
    Type SELFIT
    View Details
    Reducing Tee
    Type SELFIT
    View Details

    Video

    Description

    Advance CPVC Piping System for Fire Sprinkler System

    Astral Fire Pro pipes and fittings are specifically designed for fire sprinkler systems. They are made from a specialized thermoplastic called Chlorinated Polyvinyl Chloride (CPVC). The use of Astral Fire Pro pipes and fittings offers several advantages in sprinkler installations, including excellent hydraulic performance, easy joining, increased hanger spacing compared to other thermoplastics, and simple assembly.

    Astral Fire Pro has become the new industry standard for automatic fire sprinkler piping systems. These CPVC pipes and fittings are fully approved for use in various settings, including light and ordinary hazardous rooms or applications, as outlined by NFPA 13. This approval covers both new construction and retrofit projects, making Astral Fire Pro suitable for a wide range of buildings such as high-rise residential and commercial structures, schools, institutions, one and two-family dwellings, as well as hotels and hospitals.


    Proudly Associated With